<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Refrigerant Process Applications &#8211; PCU</title>
	<atom:link href="https://www.pcuinc.com/product-category/industrial-dispensing/refrigerant-process-applications/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.pcuinc.com</link>
	<description>Automation and Fluid Filling</description>
	<lastBuildDate>Mon, 16 Nov 2020 19:17:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.pcuinc.com/wp-content/uploads/2018/03/cropped-PCU-icon-32x32.png</url>
	<title>Refrigerant Process Applications &#8211; PCU</title>
	<link>https://www.pcuinc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Refrigerant Recovery Machine/Recycling Machine</title>
		<link>https://www.pcuinc.com/product/refrigerant-recovery-machine-recycling-machine/</link>
		
		<dc:creator><![CDATA[Kris Hatcher]]></dc:creator>
		<pubDate>Mon, 19 Aug 2019 15:29:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.pcuinc.com/product/import-placeholder-for-2392/</guid>

					<description><![CDATA[<p>PCU's Refrigerant Recycling Systems are designed to remove refrigerant safely, efficiently, and economically. Systems are adaptable to work in separate work areas or plant-wide. Once the refrigerant has been reprocessed by separating oil, moisture, and air the refrigerant may be reused. Systems operate automatically without an operator present. The recovery of recycled refrigerant helps control inventory costs. The system utilizes proven components in both standard and custom packages. Operator interface panels provide ease of use for selection criteria. Data storage and retrieval are available for verification of data and troubleshooting equipment on-site or remotely.</p>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/refrigerant-recovery-machine-recycling-machine/">Refrigerant Recovery Machine/Recycling Machine</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Options</strong></p>
<ul>
<li>Operator Interface Terminal</li>
<li>Fault indicators</li>
<li>Compressor monitoring</li>
<li>Remote monitoring</li>
<li>Adaptable to different refrigerants</li>
<li>Quick connect couplers</li>
<li>Various Capacity</li>
<li>Various safety devices</li>
<li>Tank to store liquids</li>
<li>Transfer pumps</li>
<li>Oil-less Compressors</li>
<li>Air or Water Cooled</li>
<li>PLC controlled</li>
<li>Data mining w/ printer</li>
<li>Barcode reader product identification</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/refrigerant-recovery-machine-recycling-machine/">Refrigerant Recovery Machine/Recycling Machine</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CompuCharge Refrigerant Evacuate &#038; Charge</title>
		<link>https://www.pcuinc.com/product/compucharge-refrigerant-evacuate-charge/</link>
		
		<dc:creator><![CDATA[Kris Hatcher]]></dc:creator>
		<pubDate>Mon, 19 Aug 2019 15:29:02 +0000</pubDate>
				<guid isPermaLink="false">https://www.pcuinc.com/product/import-placeholder-for-2390/</guid>

					<description><![CDATA[<p>CompuCharge Refrigerant Chargers are designed and built for accuracy and reliability by experienced engineers and assemblers. Utilizing proven components in both standard and custom packages, the system effectively evacuates and charges a precise amount of refrigerant and/or oil into various cooling system types and sizes. Operator Interface Terminals provide ease of selection for multiple charge sizes, evacuation times, vacuum check times, and vacuum check limits. Low maintenance combined with low operating costs makes these machines the industry standard. Data storage and retrieval are available for charge verification and troubleshooting equipment either on-site or remotely.</p>
<p><button id="QuoteButton">Request Quote</button></p>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/compucharge-refrigerant-evacuate-charge/">CompuCharge Refrigerant Evacuate &#038; Charge</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="row">
<div class="column">
<p><strong id="OptionsHeader">Options Available</strong></p>
<ul>
<li>Allen Bradley CompacLogix, ControlLogix, Flex I/O</li>
<li>Mitsubishi, Omron, Toyopuc, or other PLC options</li>
<li>Panelview, GOT, or other Touchscreen Operator Interface options</li>
</ul>
<p><strong id="OptionsHeader">Refrigerants</strong></p>
<ul>
<li>CO2</li>
<li>HFC-134a</li>
<li>HFO-1234yf</li>
<li>R-11</li>
<li>R-12</li>
<li>R-123</li>
<li>R-152</li>
<li>R-22</li>
<li>R-290</li>
<li>R-402a</li>
<li>R-404a</li>
<li>R-407a</li>
<li>R-408a</li>
<li>R-410a</li>
<li>R-500</li>
<li>R-507</li>
<li>R-508b</li>
<li>R-600</li>
<li>R-600a</li>
<li>R-717</li>
</ul>
</div>
<div class="column">
<p><strong id="OptionsHeader">Features and Options</strong></p>
<ul>
<li>Mass flowmeter</li>
<li>Hydraulic ram</li>
<li>Pump</li>
<li>Operator Interface Terminal</li>
<li>Charge size verification</li>
<li>Multiple selection criteria</li>
<li>Fault indicators</li>
<li>Automatic clamp charging tool</li>
<li>Automatic tool positioning</li>
<li>Quick connect charging tool</li>
<li>Industry anti-drip tooling</li>
<li>Rapid flow precision tooling</li>
<li>Pre-evacuation</li>
<li>Precision metering units</li>
<li>Various size/styles port openings</li>
<li>Rail-mounted stations</li>
<li>Base stations with rail mounted consoles</li>
<li>Data mining w/ printer</li>
<li>Heated supply lines</li>
<li>Transfer pumps</li>
<li>Line accumulators</li>
</ul>
</div>
<div class="column">
<p><strong id="OptionsHeader">Typical Data Collected</strong></p>
<ul>
<li>Product Model Number</li>
<li>Product Serial Number</li>
<li>Product Description</li>
<li>Process Start Date</li>
<li>Process Start Time</li>
<li>Cycle Number</li>
<li>Refrigerant Unit of Measure</li>
<li>Refrigerant Quantity Charged</li>
<li>Refrigerant Type Charged</li>
<li>Final Evac. Time</li>
<li>Final Evac. Level</li>
<li>Vacuum Level at Start of Vacuum Check</li>
<li>Product Vacuum Level at End of Vacuum Check</li>
<li>Vacuum Check Time</li>
<li>Total Cycle Time</li>
<li>Completion or Error Code</li>
<li>Product Pass/Fail</li>
<li>Total Refrigerant Quantity Charged.</li>
</ul>
</div>
</div>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/compucharge-refrigerant-evacuate-charge/">CompuCharge Refrigerant Evacuate &#038; Charge</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Refrigerated Booster Pump</title>
		<link>https://www.pcuinc.com/product/refrigerated-booster-pump/</link>
		
		<dc:creator><![CDATA[Kris Hatcher]]></dc:creator>
		<pubDate>Mon, 19 Aug 2019 15:29:02 +0000</pubDate>
				<guid isPermaLink="false">https://www.pcuinc.com/product/import-placeholder-for-2391/</guid>

					<description><![CDATA[<p>The PCU Model 8 x 4 Booster Pump is a refrigerated double acting, air operated pump designed for providing liquid refrigerant (at pressure) in the facility refrigerant distribution line. (R-134a at 180-220 PSIG, R410a at 360-380 PSIG) The Model 8 x 4 is capable of chilling incoming refrigerant at the maximum rate of 500 lbs. &#8230;</p>
<p class="read-more"> <a class="" href="https://www.pcuinc.com/product/refrigerated-booster-pump/"> <span class="screen-reader-text">Refrigerated Booster Pump</span> Read More &#187;</a></p>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/refrigerated-booster-pump/">Refrigerated Booster Pump</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PCU Model 8 x 4 Booster Pump is a refrigerated double acting, air operated pump designed for providing liquid refrigerant (at pressure) in the facility refrigerant distribution line. (R-134a at 180-220 PSIG, R410a at 360-380 PSIG) The Model 8 x 4 is capable of chilling incoming refrigerant at the maximum rate of 500 lbs. per hour to a temperature as low as 0 degrees F. The Model 8 x 4 is well suited for use with bulk tank refrigerant systems.</p>
<p>Service Requirements: Air pressure of 80 psi minimum at the rate of 0.5 scfm and 460/230/360-3-50/60 electric power at 1.5 KVA.</p>
<p>The post <a rel="nofollow" href="https://www.pcuinc.com/product/refrigerated-booster-pump/">Refrigerated Booster Pump</a> appeared first on <a rel="nofollow" href="https://www.pcuinc.com">PCU</a>.</p>
]]></content:encoded>
					
		
		